XY-L10A 6-60V 10A Battery Charging Control Module
৳ 700.00৳ 850.00 (-18%)
This XY-L10A Battery Charging Control Module is an intelligent programmable switch designed to manage charging for batteries rated from 6V to 60V. It features a clear, backlit LCD screen that simultaneously displays real-time voltage and charging percentages.
The XY-L10A 6-60V 10A Battery Charging Control Module is a smart, automated overcharge protection board engineered to safely govern the charging cycles of various chemistry battery packs. This high-accuracy module acts as an intelligent voltage-sensing inline switch. It handles multi-voltage configurations ranging anywhere from 6V up to 60V DC, making it highly universal. Equipped with a bright, dual-line backlit LCD display, it provides a comprehensive real-time view of critical telemetry, including exact battery voltage, calculated charge capacity percentage, and total elapsed charging runtime. [1, 2]
Rather than serving as a direct battery charger itself, this board operates as a safety gateway between your external power source and the battery. Using a heavy-duty, integrated 10A SRA-05VDC-CL relay, it mechanically engages or breaks the circuit based on your programmed thresholds. With the simplified three-button interface (SET, UP, DOWN), you can easily customize the lower limit voltage trigger (
dn) and upper limit voltage ceiling (UP). When the battery drains down to the lower threshold, the relay triggers closed, launching the charging cycle. Once the voltage hits the designated upper parameter, the circuit snaps open immediately, effectively preventing overcharging, cell degradation, or potential overheating. [2, 3, 4, 5] Key Technical Specifications
| Feature | Specification |
|---|---|
| Product Model | XY-L10A |
| Control Voltage Range | DC 6V to 60V |
| Maximum Switching Current | ≤10A |
| Voltage Control Accuracy | 0.1V |
| Telemetry Variables | Battery Voltage, Charging %, Active Time |
| Physical Dimensions | 79mm x 42mm x 16mm |
| Serial Communication | UART TTL support for remote monitoring |
Special Advanced Features
- UART Serial Configuration: Allows developers to integrate the module into broader microchip ecosystems, enabling automated parameter reading and setting via simple serial data scripts. [4, 5]
- Charging Time Control (
OP): Provides an alternate safety timeout backup mode where users can set a strict chronological limit on how long the relay can continuously stay closed. [6, 7] - Smart Backlight Management: Features a low-power mode toggled by long-pressing the UP button, allowing the screen backlight to auto-extinguish after 5 to 10 minutes of inactivity to save standby energy. [6, 8]
- Automatic Error Diagnostics: Includes built-in software validation that flashes an “ERR” warning if you mistakenly configure a lower limit voltage value that equals or exceeds the upper limit. [8, 9]